Customer: KBL Ltd
Type: Brewery
Location: Gaborone Botswana
Date: May 2008
Application: Free standing hot water tank 10 m height x 4 m diameter – clad with outer cover of riveted galvanized sheets. Problem: The galvanized layer was deteriorating, and severe rust was evident in some areas. Options: The customer was in process of deciding whether to attempt sandblast and painting at considerable cost.

Application of ZINGA: Surface preparation by means of wire brush. Rinsing with extra attention to heavily scaled areas. Brush application in two layers with 3 m²/Kg per layer.

Result: Easy ZINGA application and the appearance was to customer satisfaction.
The customer will now start to repair other galvanized surfaces as well

Gallery